FULLY ADJUSTABLE RUN-ON TIMER
ROTADJ20R5D
INSTALLATION & MAINTENANCE INSTRUCTIONS
Important
All electrical installations must be carried out by suitably qualified and competent personnel in accordance with all statutory requirements.
SETTINGS
Warning
Treat the product as live and dangerous when power is connected. Only connect power to the product
when it has been safely sealed away inside a flush box or terminal box.
- Select the desired fan START DELAY time you want by adjusting the Off-Time potentiometer, located on the
front of the unit. - Select the desired fan RUN-ON time you want by adjusting the On-Time potentiometer.
- Ensure the wall switch is open for 5 seconds after power is applied.
| Potentiometer Value | On-Time (Run-On) | Off-Time (Delay Start) |
|---|---|---|
| 0 | 0 min | 0 secs |
| 1 | 2 min | 30 secs |
| 2 | 4 min | 1 min |
| 3 | 6 min | 1.5 min |
| 4 | 8 min | 2 min |
| 5 | 10 min | 2.5 min |
| 6 | 12 min | 3 min |
| 7 | 14 min | 3.5 min |
| 8 | 16 min | 4 min |
| 9 | 18 min | 4.5 min |
| 10 | 20 min | 5 min |
WIRING DIAGRAM